This documentation is valid for speed monitors pnoz s30 from version 2. The circuit is redundant with builtin selfmonitoring. Here you find application examples on the speed monitor pnoz s30. Use the notch on the rear of the unit to attach it to a din rail. Features singlechannel or dualchannel without the detection of shorts across the input contacts 1 no auxiliary contact is a fleeting contact approvals. Estop relays, safety gate monitors farnell element14. Contactors km1 and km2 deenergise and the motor m1 is cut off in order to prevent the paper web tearing. The pnoz multi mc3p module can be found in the hardware catalogue after the gsd file has been imported. Emergency stop relays, safety gate monitors category 3, en 9541 pnoz 3 emergency stop relay and safety gate monitor in accordance with vde 011, 1198, en 602041, 1297 and iec 2041, 1198. The safety function remains effective in the case of a component failure. Ethercat and devicenet modules for configurable safety relays. Safe speed monitor pnoz s30 speed monitor for safe monitoring of standstill, speed, position and speed range. In 1987 pilz patented the first emergency stop relay to protect man and machine.
Wiring safety relay pilz pnoz and emergency stop button. Estop relays, safety gate monitors pilz safety relay. The product pnoz s30 meets the requirements of the standards en 8120, en 81 22. When using the speed monitor pnoz s30 from pilz you comply with the machinery directive with respect to the demand to safely monitor and maintain the operating status of the drive when the drive is shut down, thus protecting thee operation personnel. Pnoz 1 24vdc pilz 24 v dc safety relay dual channel with 2. Buy pilz 24 v dc safety relay dual channel with 2 safety contacts and 1 auxilary contact pnoz 1 24vdc or other safety relays online from rs for next day delivery on. The pnoz s30 safety control relay from pilz fulfils a new requirement in the field of drive monitoring. Pnoz s30 monitoring o and speed range product type. Safely monitor speed, standstill, position and direction of rotation of your machines with the speed monitor pnoz s30 in accordance with en iso 8491 up to pl e and in accordance with en iec 62061 up to sil cl 3.
Going to be working with the pilz pnoz s30 and they have electrical cad data on the website in an edz format. Im not sure what exactly this contains, but i am quite interested. Pnoz 8 24vdc pilz 24 v dc safety relay dual channel with 3. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. Speed monitor for safe monitoring of standstill, speed, position and speed range. Compare pricing for pilz pnozx4 across 3 distributors and discover alternative parts, cad models, technical specifications, datasheets, and more on octopart. Pnozmulti control system is reset, the expansion module pnoz mc3p is configured and started automatically. Operating manual pnoz s30 1001715en 6 introduction validity of documentation this documentation is valid for speed monitors pnoz s30 from version 2. Emergency stop relays, safety gate monitors category 4, en 9541 pnoz 8 emergency stop relay and safety gate monitor in accordance with vde 011, 1198, en 602041, 1297 and iec 2041, 1198. Pnoz v30 s 24vdc pilz 474790 safety relays in stock.
Estop relays, safety gate monitors allied electronics. Can be used as safety gate monitor, emergency stop unit or light curtain monitoring semiconductor outputs for healthy and fault signals solid state outputs are rated at 50ma at 24vdc with short circuit protection incorporated single and dual channel input recognises short circuited inputs a safety cutout is triggered should an earth fault or a short across the key. The configuration is described in detail in the pnozmulti configurators online help. The pnoz s30 safety control relay from pilz fulfils a new requirement in the field of drive monitoring, enabling the operating status to be safely monitored and maintained when the drive is brought to a standstill i. Follow the first link to download an eds file for the pnoz mmc4p dn from the pilz website, or the second link for more information about the full range of pnozmulti mini communications modules. Pnoz s3 operating manual pnoz s3 295en11 5 introduction validity of documentation this documentation is valid for the product pnoz s3. Pilz pdf downloads pilz are well known as one of the uks leading suppliers of machinery safety equipment, software, training and consultancy services you will find a selection featured in our new lc automation product catalogue. Technical support is available from pilz round the clock. Description the example shows the pnoz s30 monitoring a safe speed range and safely limited speed.
The pnoz brand is now synonymous with safety relays. Pnoz s30 monitoring o of rotational speed and speed. The computeraided design cad files and all associated content posted to this website are created, uploaded, managed and owned by third party users. Suggestions and comments for improving this documentation will be gratefully received. Pnoz s30 is suitable for safe monitoring of speed, standstill, position and direction. The pnoz s30 a1 monitors the speed of a drive to the set limit value. Customers often ask if our lead times are accurate, and the answer is yes.
This service is provided free of charge beyond standard business hours. Base units are all safety relays with feedback loop monitoring. Buy pilz pnoz s30 24 240 v acdc safety relay single channel with 2 safety contacts and 2. Quick time engineering inc is not an authorized dealer, agent or affiliate of any of the designer, brands, or manufacturer, the products of which are offered for sale on. Pnoz 16 operating manual pnoz 16 1003517en07 5 introduction validity of documentation this documentation is valid for the product pnoz 16. Leds indicate the status of the expansion module on profibus. Pnoz s10 operating manual pnoz s10 21402en08 3 safety relay pnoz s10 the unit meets the requirements of en 6094751, en 602041 and vde 011. Operating manual pnoz s30 1001715en18 7 1 introduction 1. The contact expansion module is used to increase the number of instantaneous safety contacts available on a base unit. Pnoz c2 operating manual pnoz c2 22212en02 6 safety features the relay meets the following safety requirements.
Pdf 1001758en01201011 pnoz s30 pilz pnoz x1 pilz 779 211 pnoz 1 mttf pilz pnoz x3 safety relay pilz pnoz x3 pnozmulti incremental encoders htl pilz p11 pilz 779 201. Information the gsd file is available on the internet at. Pnoz 1 24vdc pilz 24 v dc safety relay dual channel with. Monitoring of direction of rotation in accordance with en iso 8491 up to pl e and en iec 62061 up to sil cl 3. Artisan technology group is your source for quality. Pnoz safety relays quickly progressed to be the worlds most commonly used safety relays. Pnoz s30 monitoring of rotational speed and speed range. The pnoz mmc4p dn can be configured using any version of the pnozmulti configurator software from version 8. Safetynet p, the spirit of safety are registered and protected trademarks of pilz gmbh. Pilz pnoz x1 pilz 779 211 pnoz 1 mttf pilz pnoz x3 safety relay pilz pnoz x3 pnozmulti incremental encoders htl pilz p11 pilz 779 201. Safety relay, 3no 24vac online from elcodis, view and download pnoz x2. If the configured maximum speed is exceeded, the pnoz s30 switches off the safety contact rel. Page 1 pnoz s30 safety relays operating manual1001715en page 2 preface this document is the original document.